Peripheral Integrated Circuits
Specifications:
Parameter
Min
Typ
Max
Unit
Volts
Input Voltage
4.5
36
1
Input Voltage Signal
2
200
mV
2
Input Current
10
μ A
Supply Current – Off
2.2
3.0
3.8
mA
3
(Input Voltage=12V)
Supply Current – On
7.0
8.0
9.0
mA
3
(Input Voltage=12V)
Output Duty Cycle
40
50
60
%
Regulated Voltage Output
3.0
3.3
3.6
Volts
Current Supplied by Regulated Voltage Output
10
mA
Operating Temperature Range
-40
+150
° C
Frequency of Operation
0
10k
Hz
ESD
2000
V
4
Absolute Maximum Ratings
Parameter
Limit
Supply Voltage
45V
Reverse Battery Voltage
-60V
Output Current
16mA
Junction Temperature Range
-40 ° C to +170 ° C
Storage Temperature Range
-65 ° C to +170 ° C
Signal Output
10
Current
Output
(mA)
5
Time
Notes:
1.
The supply voltage must appear across the power and ground terminals of the part. Any additional voltage drop due to the
presence of a series resistor is not included in this specification.
2.
Input signal range can be adjusted by programming the amplifier gain to a specific value; contact NVE for details.
3.
Supply currents can be factory programmed to different levels, for example 3 mA and 6 mA, or 7 mA and 14 mA; contact
NVE for details.
4.
Pin-to-pin voltage, Human Body Model for ESD.
- 71 -
www.nve.com phone: 952-829-9217 fax: 952-829-9189